Architectural Preview
Building Codes and Green Building Standards
The building code arena is every changing; it can be a daunting task to keep up. Adding Energy Star in to the mix along with various evolving ‘green building’ standards; only makes the task bigger.
As a leader in the industry, CrystaLite strives to stay ahead of the pack by producing products that exceed these standards. Our CrystaLite’s ES Skylight backs this claim as we are the first (and currently the only) manufacturer of a 30/30 skylight eligible for the Federal Tax Credit resulting from the American Recovery and Reinvestment Tax Act of 2009.
This area of our website serves as our outlet to deliver product information and other relative information to you in regards to the building codes and the emerging ‘green building’ standards.
ENERGY STAR
The industries most well-known residential performance standard.LEED v2.2 / v3.0
The US Green Building Council green standard for commercial buildings.Skylight Products
CrystaLite skylights are NAMI certified and NFRC rated for thermal performance; U-Factor, SHGC, Visible Light Transmittance.
Standard skylights are NAMI certified to the NAFS Standard [AAMA/WDMA/CSA] for air infiltration, water penetration and structural loading. Custom Metal Frame Skylights have been independantly tested to the appropriate ASTM and AAMA standards required by the building codes.
| CSI Format Product | PDF/CAD | Specs | LEED |
|---|---|---|---|
| 08 62 00 Unit Skylight (5841 PVC/Alum Frame) | View | DOC | View |
| 08 62 00 Unit Skylight (5842 PVC/Alum Fram) | View | DOC | View |
| 08 62 00 Unit Skylight (5843 PVC/Alum Frame) | View | DOC | View |
| 08 62 00 Venting Skylight (5830 Opener) | View | DOC | View |
| 08 62 00 Unit Skylight (3962 Aluminum Frame) | View | DOC | View |
| 08 62 00 Unit Skylight (3921 Thermal Break) | View | DOC | View |
| 08 62 70 Tubular Daylighting (Tubular Skylight) | DOC | View | |
| 08 67 00 Skylight Protection (Safety Grids) | DOC | View | |
| → 07 72 60 Fall Protection (Safety Grids) | DOC | View | |
| → 10 73 00 Protective Covers (Safety Grids) | DOC | View | |
| 08 63 00 Metal Framed Skylight (Customs) | View | DOC | View |
| → 10 73 13 Awnings (Customs) | View | DOC | View |
| → 10 73 16 Canopies (Customs) | View | DOC | View |
| → 10 73 26 Walkway Coverings (Customs) | View | DOC | View |
| → 10 73 43 Transit Stop Shelters (Customs) | View | DOC | View |
| → 13 34 00 Fabricated Structures (Customs) | View | DOC | View |
| → 13 34 13 Glazed Structures (Customs) | View | DOC | View |
Railing Products
The Flash Player and a browser with Javascript support are needed..
Glass Panel Railing
Available in a number of tints, CrystaLite glass panel railing systems create the perfect windbreak without any loss of view. Glass panels are excellent for exterior decks, balconies and stairs, yet sleek and elegant for interior railings.
Laser Etched Glass
Now Available with CrystaLite glass panel railing systems or with raw glass orders! An alternative to pattern glass for creating a truly custom design. Also a great solution to utilize instead of frosted glass when an installation may require some privacy blocking. The possibilities are endless. Consult with your CrystaLite sales representative for more information.
Pattern Glass
We offer more than clear glass in our railing systems. Matelux, Niagra, and Rain are popular glass options when privacy is a concern. Utilizing our glass clips, your glass rail can be extended taller to provide greater wind block as well.
The Flash Player and a browser with Javascript support are needed..
Stainless Cable Railing
Made from strong and weather-tough 1/8″ stainless steel cable, CrystaLite cable rail is excellent for exterior rails and fences, yet sleek and elegant for interior railings. The special easy-to-use fittings are hidden in the end posts.
Cable assemblies are available separate from our aluminum rail system as well, and are available with 3 mounting options.
System Requirements
Cable runs are limited to 50 feet between anchor posts and 4 foot center spans for intermediate posts; 3 feet for commercial.
The Flash Player and a browser with Javascript support are needed..
Aluminum Picket Railing
For many classic home styles, our white picket railing is the perfect fit. Picket railing is a popular choice when stairs are part of the installation. It is also a lighter application which is often preferred for gates.
Railing Details
Glass Panel Rail
Deck Mount
1.75″ Post – 9005
2.5″ Post – 9006
3.5″ Post – 9060
Side Mount
1.75″ Post – 9005
2.5″ Post – 9006
3.5″ Post – 9060
Stainless Cable Rail
Deck Mount
1.75″ Post – 9005
2.5″ Post – 9006
3.5″ Post – 9060
Side Mount
1.75″ Post – 9005
2.5″ Post – 9006
3.5″ Post – 9060
Aluminum Picket Rail
Deck Mount
1.75″ Post – 9005
2.5″ Post – 9006
3.5″ Post – 9060
Side Mount
1.75″ Post – 9005
2.5″ Post – 9006
3.5″ Post – 9060
CrystaLite railings are structurally designed and stamped by an independant structural engineer. Railing systems have been rated to accommodate high wind loads and exposure ratings set forth by local building codes. CrystaLite will select the appropriate post size and spacing to meet code requirements including: Exposure B, C, and D with wind speeds up to 120 mph.
| CSI Format Product | PDF/CAD | Specs | LEED |
|---|---|---|---|
| 05 73 00 Decorative Metal Railing | View | DOC | |
| → 05 73 13 Glazed Railing (Glass Rail) | View | DOC | |
| → 05 73 16 Wire Rope Railings (Cable Rail) | View | DOC | |
| → 05 15 19 Stainless Wire Rope (SS Cable) | View | DOC |
Other Products
| CSI Format Product | PDF/CAD | Specs | LEED |
|---|---|---|---|
| 08 45 00 Translucent Roof (Corru. Polycarb) | DOC | ||
| 08 45 00 Translucent Roof (Polycarb Multiwall) | DOC | ||
| 08 84 00 Plastic Glazing (Corrugated Polycarb) | DOC | ||
| 08 84 00 Plastic Glazing (Polycarb Multiwall) | DOC | ||
| 23 34 00 Solar Powered Attic Fan (Solar Fan) | DOC |
CrystaLite proudly introduces the markets first skylight to qualify for the 30/30 Federal Tax Credit resulting from the American Recovery and Reinvestment Tax Act of 2009. The ES Skylight is 53% more efficient than the new 2010 ENERGY STAR criteria, and retains a transparent view outwards with an exceptional visible transmittance value! View Tax Credit Information.
High Visible Light AND Clear Glass
The industry trend towards advances in thermal insulation results in an opaque glazing solution. We did not follow that trend. The new ES Skylight not only retains a high visible light transmittance (VT) of 0.49, but also retains a see through view outwards – like clear glass.
Tax Credit Criteria
Energy Star windows, doors, and skylights may qualify for the Federal Tax Credit, but not all of them. The Federal Tax Credit set levels that far exceed those set by Energy Star. Unlike Energy Star, the criteria for the tax credit is the same for windows, doors, and skylights. The products must have a U-Factor and a Solar Heat Gain Coefficent (SHGC) of 0.30 or lower.
Currently, CrystaLite’s ES Skylight is the only skylight on the market eligible. Refer to our Energy Star and Tax Credit Simplified handout for more information, as well as the Energy Star website.
Documentation
Homeowner’s seeking to receive the tax credit do not have to submit a copy of the Manufacturer’s Certification Statement with their tax return, but must keep a copy of the statement for their records.
NFRC Values
| Glazing | U-Factor | SHGC | VT | Type |
|---|---|---|---|---|
| Temp / Temp / Temp | 0.26 | 0.26 | 0.49 | Cardinal LoE3-366 |
| Temp / Temp / Lam | 0.26 | 0.25 | 0.48 | Cardinal LoE3-366 |
ENERGY STAR Compliant in Northern Climate Zone
Standard Sizes
Skylights are designed to fit over the curb like a ‘lid on a shoe box.’
Model sizes are based on Outside Curb Dimensions (OCD).
| Model | OCD | |
|---|---|---|
| 1838 | 17.5″ x 37.5″ | |
| 1850 | 17.5″ x 49.5″ | |
| 1874 | 17.5″ x 73.5″ | |
| 2626 | 25.5″ x 25.5″ | 2×2 |
| 2634 | 25.5″x33.5″ | |
| 2638 | 25.5″x37.5″ | 2×3 |
| 2650 | 25.5″ x 49.5″ | 2×4 |
| 2662 | 25.5″ x 61.5″ | |
| 2674 | 25.5″ x 73.5″ | 2×6 |
| Model | OCD | |
|---|---|---|
| 2698 | 25.5″ x 97.5″ | |
| 3434 | 33.5″ x 33.5″ | |
| 3438 | 33.5″ x 37.5″ | |
| 3450 | 33.5″ x 49.5″ | |
| 3474 | 33.5″ x 73.5″ | |
| 3838 | 37.5″x37.5″ | |
| 3850 | 37.5″x349.5″ | |
| 3862 | 37.5″ x 61.5″ | |
| 5050 | 49.5″ x 49.5″ | 4×4 |
Note: 5843 Frame is limited to 2626, 2638, 2650, and 2674 model sizes only.
Note: ES Skylight and 5830 Frame are NOT available in 3874, 3898, 5062, and 5074 model sizes.
Pricing
5842 PVC / Aluminum Frame
This is our most common curb mount frame featuring a PVC interior frame and a bronze or clear anodized aluminum cap. The PVC interior provides an excellent thermal break. Custom sizes are available. All corners are welded – interior and exterior.
NFRC Values
| Glazing | U-Factor | SHGC | Type |
|---|---|---|---|
| Temp / Temp | 0.50 | 0.40 | Cardinal 272 |
| Temp / Lam | 0.51 | 0.39 | Cardinal 272 |
| Double Dome | 0.69 | 0.72 | Clear |
| Double Dome | 0.69 | 0.50 | White |
| Triple Dome | 0.51 | 0.65 | Clear |
| Triple Dome | 0.51 | 0.46 | White |
ENERGY STAR Compliant in Northern Climate Zone
Standard Sizes
Skylights are designed to fit over the curb like a ‘lid on a shoe box.’
Model sizes are based on Outside Curb Dimensions (OCD).
| Model Size | OCD | Call-Out |
|---|---|---|
| 1838 | 17.5″ x 37.5″ | |
| 1850 | 17.5″ x 49.5″ | |
| 1874 | 17.5″ x 73.5″ | |
| 2626 | 25.5″ x 25.5″ | 2×2 |
| 2634 | 25.5″ x 33.5″ | |
| 2638 | 25.5″ x 37.5″ | 2×3 |
| 2650 | 25.5″ x 49.5″ | 2×4 |
| 2662 | 25.5″ x 61.5″ | |
| 2674 | 25.5″ x 73.5″ | 2×6 |
| 2698 | 25.5″ x 97.5″ | |
| 3434 | 33.5″ x 33.5″ |
| Model Size | OCD | Call-Out |
|---|---|---|
| 3438 | 33.5″ x 37.5″ | |
| 3450 | 33.5″ x 49.5″ | |
| 3474 | 33.5″ x 73.5″ | |
| 3838 | 37.5″ x 37.5″ | |
| 3850 | 37.5″x349.5″ | |
| 3862 | 37.5″ x 61.5″ | |
| 3874 | 37.5″ x 73.5″ | |
| 3898 | 37.5″ x 97.5″ | |
| 5050 | 49.5″ x 49.5″ | 4×4 |
| 5062 | 49.5″ x 61.5″ | |
| 5074 | 49.5″ x 73.5″ |
Note: 5843 Frame is limited to 2626, 2638, 2650, and 2674 model sizes only.
Note: ES Skylight and 5830 Frame are NOT available in 3874, 3898, 5062, and 5074 model sizes.
PDF / DWG Skylight Details
Pricing
5843 PVC / Aluminum Frame
This is our production line frame, offered in models 2626, 2638, 2650, and 2674 sizes only; and limited to insulated glass glazing only.
NFRC Values
| Glazing | U-Factor | SHGC | Type |
|---|---|---|---|
| Temp / Temp | 0.50 | 0.39 | Cardinal 272 |
| Temp / Lam | 0.48 | 0.39 | Cardinal 272 |
ENERGY STAR Compliant in Northern Climate Zone
Standard Sizes
| Model Size | OCD | Call-Out |
|---|---|---|
| 2626 | 25.5″ x 25.5″ | 2×2 |
| 2638 | 25.5″ x 37.5″ | 2×3 |
| 2650 | 25.5″ x 49.5″ | 2×4 |
| 2674 | 25.5″ x 73.5″ | 2×6 |
Pricing
5841 PVC / Aluminum Frame
Often referred to as the Sky Blind frame, this frame comes with a 1 3/8″ PVC leg that drops down into the light well providing a surface to mount the Sky Blind. The interior leg also provides for flush alignment with drywall finishes.
NFRC Values
| Glazing | U-Factor | SHGC | Type |
|---|---|---|---|
| Temp / Temp | 0.49 | 0.38 | Cardinal 272 |
| Temp / Lam | 0.50 | 0.37 | Cardinal 272 |
| Double Dome | 0.67 | 0.67 | Clear |
| Double Dome | 0.67 | 0.47 | White |
| Triple Dome | 0.50 | 0.61 | Clear |
| Triple Dome | 0.50 | 0.43 | White |
ENERGY STAR Compliant in Northern Climate Zone
Standard Sizes
Skylights are designed to fit over the curb like a ‘lid on a shoe box.’
Model sizes are based on Outside Curb Dimensions (OCD).
| Model Size | OCD | Call-Out |
|---|---|---|
| 1838 | 17.5″ x 37.5″ | |
| 1850 | 17.5″ x 49.5″ | |
| 1874 | 17.5″ x 73.5″ | |
| 2626 | 25.5″ x 25.5″ | 2×2 |
| 2634 | 25.5″ x 33.5″ | |
| 2638 | 25.5″ x 37.5″ | 2×3 |
| 2650 | 25.5″ x 49.5″ | 2×4 |
| 2662 | 25.5″ x 61.5″ | |
| 2674 | 25.5″ x 73.5″ | 2×6 |
| 2698 | 25.5″ x 97.5″ | |
| 3434 | 33.5″ x 33.5″ |
| Model Size | OCD | Call-Out |
|---|---|---|
| 3438 | 33.5″ x 37.5″ | |
| 3450 | 33.5″ x 49.5″ | |
| 3474 | 33.5″ x 73.5″ | |
| 3838 | 37.5″ x 37.5″ | |
| 3850 | 37.5″x349.5″ | |
| 3862 | 37.5″ x 61.5″ | |
| 3874 | 37.5″ x 73.5″ | |
| 3898 | 37.5″ x 97.5″ | |
| 5050 | 49.5″ x 49.5″ | 4×4 |
| 5062 | 49.5″ x 61.5″ | |
| 5074 | 49.5″ x 73.5″ |
Note: 5843 Frame is limited to 2626, 2638, 2650, and 2674 model sizes only.
Note: ES Skylight and 5830 Frame are NOT available in 3874, 3898, 5062, and 5074 model sizes.
PDF / DWG Skylight Details
Pricing
3962 PVC / Aluminum Frame
Standard aluminum frame featuring aluminum interior and exterior members. Custom sizes are available. This frame is also used for triangle shaped and multi faceted curb mount units.
NFRC Values
| Glazing | U-Factor | SHGC | Type |
|---|---|---|---|
| Temp / Temp | 0.58 | 0.41 | Cardinal 272 |
| Temp / Lam | 0.59 | 0.40 | Cardinal 272 |
| Double Dome | 0.76 | 0.73 | Clear |
| Double Dome | 0.76 | 0.51 | White |
| Triple Dome | 0.59 | 0.67 | Clear |
| Triple Dome | 0.59 | 0.47 | White |
ENERGY STAR Compliant in Northern Climate Zone
Standard Sizes
Skylights are designed to fit over the curb like a ‘lid on a shoe box.’
Model sizes are based on Outside Curb Dimensions (OCD).
| Model Size | OCD | Call-Out |
|---|---|---|
| 1838 | 17.5″ x 37.5″ | |
| 1850 | 17.5″ x 49.5″ | |
| 1874 | 17.5″ x 73.5″ | |
| 2626 | 25.5″ x 25.5″ | 2×2 |
| 2634 | 25.5″ x 33.5″ | |
| 2638 | 25.5″ x 37.5″ | 2×3 |
| 2650 | 25.5″ x 49.5″ | 2×4 |
| 2662 | 25.5″ x 61.5″ | |
| 2674 | 25.5″ x 73.5″ | 2×6 |
| 2698 | 25.5″ x 97.5″ | |
| 3434 | 33.5″ x 33.5″ |
| Model Size | OCD | Call-Out |
|---|---|---|
| 3438 | 33.5″ x 37.5″ | |
| 3450 | 33.5″ x 49.5″ | |
| 3474 | 33.5″ x 73.5″ | |
| 3838 | 37.5″ x 37.5″ | |
| 3850 | 37.5″x349.5″ | |
| 3862 | 37.5″ x 61.5″ | |
| 3874 | 37.5″ x 73.5″ | |
| 3898 | 37.5″ x 97.5″ | |
| 5050 | 49.5″ x 49.5″ | 4×4 |
| 5062 | 49.5″ x 61.5″ | |
| 5074 | 49.5″ x 73.5″ |
Note: 5843 Frame is limited to 2626, 2638, 2650, and 2674 model sizes only.
Note: ES Skylight and 5830 Frame are NOT available in 3874, 3898, 5062, and 5074 model sizes.
PDF / DWG Skylight Details
Pricing
3921 PVC / Aluminum Frame
Aluminum thermal break frame features a resin core within the interior aluminum extrusion; improving the thermal properties.
NFRC Values
| Glazing | U-Factor | SHGC | Type |
|---|---|---|---|
| Temp / Temp | 0.54 | 0.38 | Cardinal 272 |
| Temp / Lam | 0.55 | 0.38 | Cardinal 272 |
| Double Dome | 0.76 | 0.68 | Clear |
| Double Dome | 0.76 | 0.47 | White |
| Triple Dome | 0.58 | 0.62 | Clear |
| Triple Dome | 0.58 | 0.44 | White |
ENERGY STAR Compliant in Northern Climate Zone
Standard Sizes
Skylights are designed to fit over the curb like a ‘lid on a shoe box.’
Model sizes are based on Outside Curb Dimensions (OCD).
| Model Size | OCD | Call-Out |
|---|---|---|
| 1838 | 17.5″ x 37.5″ | |
| 1850 | 17.5″ x 49.5″ | |
| 1874 | 17.5″ x 73.5″ | |
| 2626 | 25.5″ x 25.5″ | 2×2 |
| 2634 | 25.5″ x 33.5″ | |
| 2638 | 25.5″ x 37.5″ | 2×3 |
| 2650 | 25.5″ x 49.5″ | 2×4 |
| 2662 | 25.5″ x 61.5″ | |
| 2674 | 25.5″ x 73.5″ | 2×6 |
| 2698 | 25.5″ x 97.5″ | |
| 3434 | 33.5″ x 33.5″ |
| Model Size | OCD | Call-Out |
|---|---|---|
| 3438 | 33.5″ x 37.5″ | |
| 3450 | 33.5″ x 49.5″ | |
| 3474 | 33.5″ x 73.5″ | |
| 3838 | 37.5″ x 37.5″ | |
| 3850 | 37.5″x349.5″ | |
| 3862 | 37.5″ x 61.5″ | |
| 3874 | 37.5″ x 73.5″ | |
| 3898 | 37.5″ x 97.5″ | |
| 5050 | 49.5″ x 49.5″ | 4×4 |
| 5062 | 49.5″ x 61.5″ | |
| 5074 | 49.5″ x 73.5″ |
Note: 5843 Frame is limited to 2626, 2638, 2650, and 2674 model sizes only.
Note: ES Skylight and 5830 Frame are NOT available in 3874, 3898, 5062, and 5074 model sizes.
PDF / DWG Skylight Details
5830 PVC / Aluminum Frame
Our most popular opening skylight frame features a PVC interior. A PVC leg drops down into the light well which provides a flat surface to attach the chain drive Truth opener and aligns flush with interior drywall.. Option for hand crank (Truth angle drive) vs. 6′-10′ pole (Truth straight drive) should be determined at time of order. Screen is standard. Designed for standard 1-1/2″ thick curbing only.
NFRC Values
| Glazing | U-Factor | SHGC | Type |
|---|---|---|---|
| Temp / Temp | 0.51 | 0.36 | Cardinal 272 |
| Temp / Lam | 0.51 | 0.36 | Cardinal 272 |
| Double Dome | 0.68 | 0.66 | Clear |
| Double Dome | 0.68 | 0.46 | White |
| Triple Dome | 0.52 | 0.60 | Clear |
| Triple Dome | 0.52 | 0.42 | White |
ENERGY STAR Compliant in Northern Climate Zone
Standard Opener Sizes
Skylights are designed to fit over the curb like a ‘lid on a shoe box.’
Model sizes are based on Outside Curb Dimensions (OCD).
| Model | OCD | |
|---|---|---|
| 1838 | 17.5″ x 37.5″ | |
| 1850 | 17.5″ x 49.5″ | |
| 1874 | 17.5″ x 73.5″ | |
| 2626 | 25.5″ x 25.5″ | 2×2 |
| 2634 | 25.5″x33.5″ | |
| 2638 | 25.5″x37.5″ | 2×3 |
| 2650 | 25.5″ x 49.5″ | 2×4 |
| 2662 | 25.5″ x 61.5″ | |
| 2674 | 25.5″ x 73.5″ | 2×6 |
| Model | OCD | |
|---|---|---|
| 2698 | 25.5″ x 97.5″ | |
| 3434 | 33.5″ x 33.5″ | |
| 3438 | 33.5″ x 37.5″ | |
| 3450 | 33.5″ x 49.5″ | |
| 3474 | 33.5″ x 73.5″ | |
| 3838 | 37.5″x37.5″ | |
| 3850 | 37.5″x349.5″ | |
| 3862 | 37.5″ x 61.5″ | |
| 5050 | 49.5″ x 49.5″ | 4×4 |
Note: 5843 Frame is limited to 2626, 2638, 2650, and 2674 model sizes only.
Note: ES Skylight and 5830 Frame are NOT available in 3874, 3898, 5062, and 5074 model sizes.
PDF / DWG Skylight Details
Pricing
The Flash Player and a browser with Javascript support are needed..
You Design It
You envision it, CrystaLite designs and builds it. For residential, commercial and industrial applications, CrystaLite has designed and manufactured a wide range of custom skylights which can bring added dimensions to a building’s aesthetics.
We have three basic frame weight options: light, medium, and heavy. All CrystaLite frames are structurally engineered to meet or exceed local building code requirements. Medium and heavy frames are designed to span greater distances than light frames. Light frames can be used in place of heavier frame types where supports such as rafters are in place, supplied by other.
We offer bronze and clear anodized as standard finishes. We can provide custom color match paint finishes, based on color samples provided. Engineering
CrystaLite has the expertise to ensure the structural integrity that your grand vision demands. If you are looking for a way to incorporate natural light in your building project, CrystaLite Skylites are your clear choice.
Skylight PDF/Cad Details
Standard Unit Skylights
5841 Skylight Details
5842 Skylight Details
5843 Skylight Details
3962 Skylight Details
3921 Skylight Details
5830 Opener Skylight Details
Sloped Glazing
3962 Light Frame
4843 Medium Frame
30258 Heavy Frame
Ridge
3962 Light Frame
4843 Medium Frame
30258 Heavy Frame
Hip Ridge
3962 Light Frame
4843 Medium Frame
30258 Heavy Frame
Pyramid
3962 Light Frame
4843 Medium Frame
30258 Heavy Frame
Barrel Vault
Insulated
Non-Insulated
Cluster System
Energy Star
2010 Energy Star Criteria for Windows, Doors, & Skylights
The Energy Star criteria for skylights have been lowered from a U-Factor of 0.60 to a 0.55 for most of CrystaLite’s dealer area. Refer to the maps and criteria below.
We are currently in a labeling transition period, which will last until April 1st, in which manufacturers can label to the old standard or the new. CrystaLite has already begun rolling over to the new labeling procedures.
Full criteria changes are available in the Program Requirements and as well as from the Energy Star website.
Energy Star and the 30/30 Federal Tax Credit
Energy Star skylights may qualify for the Federal Tax Credit, but not all of them. The Federal Tax Credit set levels that far exceed those set by Energy Star. Currently, CrystaLite’s ES Skylight is the only skylight on the market eligible. Refer to our Energy Star and Tax Credit Simplified handout for more information, as well as the Energy Star website.
LEED v2.2 / v3.0 Verification
CrystaLite skylights, overhead glazing, and sunrooms can help project teams achieve LEED Certification. These products always satisfy two LEED prerequisites and always facilitates the achievement of 1-17 LEED credits under the LEED for New Construction and Major Renovation (version 2.2) system; and 1-27 LEED credits under the LEED for New Construction and Major Renovation (version 3.0) system.
| Environmental Feature | LEED v2.2 | LEED v3.0 | ||
|---|---|---|---|---|
| Credit | Points | Credit | Points | |
| Energy Compliance | EA Prereq 2 | Prereq | EA Prereq 2 | Prereq |
| Energy Efficiency | EA 1 | 1-10 | EA 1 | 1-19 |
| Recycled Content | MR 4.1 | 1-2 | MR 4.1 | 1-2 |
| Regional Materials | MR 5.1 | 1-2 | MR 5.1 | 1-2 |
| Ventilation | IEQ Prereq 1 | Prereq | IEQ Prereq 1 | Prereq |
| Air Quality | IEQ 1 | 1 | IEQ 1 | 1 |
| Daylight | IEQ 8.1 | 1-2 | IEQ 8.1 | 1-2 |
| Improved Views | IEQ 8.2 | 1 | IEQ 8.2 | 1 |
Environmental Feature Details and Definitions
Energy Code Compliance
Buildings seeking LEED Certification must meet or exceed the ASHRAE 90.1 Standard for energy performance. CrystaLite skylights, overhead glazing, and sunrooms are NFRC certified and rated; and have been tested and verified for air infiltration, water penetration, and structural loading exceeding the prescribed criteria as outlined by ASHRAE 90.1. Unit skylights are certified by the National Accreditation & Management Institute (NAMI) to the NAFS Standard (AAMA/WDMA/CSA 101/I.S. 2/A440). CrystaLite field glazed systems have been tested by an AAMA/ISO accredited test laboratory and verified by an independent structural engineer.
Energy Efficiency
Optimizing energy performance results in lowering operating costs (thus saving money for the building owner), and this use of less energy means using less environmental resources. CrystaLite skylights, overhead glazing, and sunrooms make buildings more energy efficient by delivering natural lighting and, when utilizing opening skylights, deliver natural ventilation to indoor spaces. More daylight and natural ventilation results in less use of electrical and mechanical systems; and the use of less electromechanical systems results in better energy performance.
Recycled Content
Using materials containing recycled content is intelligent and resourceful. The use of recycled materials reduces waste and reducing waste helps the environment. CrystaLite skylights, overhead glazing, and sunrooms are manufactured with recycled aluminum and glass material content.
Regional Materials
Buying locally manufactured products reduces environmental pollution associated with transportation. CrystaLite skylights, overhead glazing, and sunrooms are manufactured in the state of Washington. The majority of the materials for these products are extracted, sourced, and produced within 500 miles of CrystaLite’s manufacturing plant in Everett.
Ventilation
Buildings seeking LEED must comply with ASHRAE Standard 62.1 – Ventilation for Acceptable Indoor Air Quality. Manual and mechanical operators are available for CrystaLite skylights, overhead glazing, and sunrooms. Operable products facilitate ventilation code compliance, increase the natural ventilation for indoor spaces, and reduce energy costs – all of which positively impact the environment.
Daylight and Views to the Outside
The amount of daylight and views in a space directly impacts occupant comfort. Daylighting an interior space and giving the interior space a connection to the outdoor environment makes occupants feel better and thus enhances occupant comfort and improves human performance. Designing spaces to have more daylighting also reduces reliance n electromechanical systems, thus saving costs and reducing environmental impacts associated with energy use. CrystaLite sunrooms and vertical wall systems are your clear choice for providing optimal views to the outside environment.
Skylight Code Compliance
CrystaLite skylights have been tested and certified to all standards and requirements set forth by the building and energy codes.
Glass skylights are typically built for residential skylights utilizing tempered glass for both panes in an insulated unit. Some code requirements exist which require laminated glass. All commercial glazing applications typically require laminated glass for the inboard pane. Review the following handout for more information.
NFRC Rated for Energy Efficiency
All CrystaLite skylights and custom slope glazings have been NAMI certified and NFRC rated for U-factor, Solar Heat Gain (SHGC), and Visible Light Transmittance (VT).
Standard Skylight Structural Testing
Standard skylights are NAMI certified to the NAFS Standard per commercial and residential code requirements for air infiltration, water penetration and structural loading; commonly referred to as ‘AAMA Testing.’
Slope Glazing Structural Testing
- Deflections in structural members shall be limited to L/175 under fully loaded conditions, per ASTM E 330 at 150% of positive and negative wind load design pressures for a duration required by design wind velocity without assembly evidencing material and deflection failures or permanent deformation of structural members exceeding 0.2% of span. Compliant to International Building Code 2006, section 2405 Sloped Glazing and Skylights.
- Air infiltration per. Air leakage shall not exceed 0.06 cfm/sq. ft. of assembly surface when tested with a pressure of 6.24 psf. Compliant to IECC 402.4 Air Leakage.
- Water penetration per ASTM E 331. No water penetration when tested with a pressure differential of 30.0 psf. (Light Frame limited to 6.24 psf). System designed to drain migrating moisture occurring from condensation to exterior through weep drainage network. Compliant to International Building Code 2006, section 1403.2 Weather Protection.
Green Building Criteria
Green building practices beyond Energy Star are becoming more main stream, and skylights have a big role in green building design by allowing free, natural, daylight into a home or business. Regional manufacturing and recycled content are important roles as well. CrystaLite will assist in selecting the appropriate frame and glazing configuration to meet your green building needs, including assistance in achieving LEED credits for commercial buildings and Green Globes points for residential.